[BOTH] DC generator losses and efficiency - part 1

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Copper loss: wire heating in windings

    Wire heating is copper loss: Pcu = I^2 x R in the windings. Double the current, four times the heat. Like an extension cord warming when cooker and iron box run together. Recall: copper loss depends on what? (Current)

  2. Fact 2 of 12

    Shunt field copper loss stays steady

    Shunt field copper loss = If^2 x Rf, and it stays nearly fixed while field excitation is fixed. Like a fan motor coil that stays warm all day at one setting. Recall: is shunt field copper loss constant or variable? (Constant)

  3. Fact 3 of 12

    Hysteresis loss: the core's magnetic lag

    Hysteresis loss is energy lost as the core resists flipping magnetism each cycle. Steinmetz law: Ph = eta x Bmax^1.6 x f x V. Like a stiff gate hinge that squeaks each swing. Recall: who gave the hysteresis law? (Steinmetz)

  4. Fact 4 of 12

    Eddy current loss: swirling currents in iron

    Eddy loss is heat from swirling currents inside the iron core. Pe = Ke x Bmax^2 x f^2 x t^2, so thin insulated laminations cut it. Like a thin stacked sheet heating less than a solid iron bar. Recall: what cuts eddy loss? (Laminations)

  5. Fact 5 of 12

    Iron loss = hysteresis + eddy current

    Iron loss is hysteresis plus eddy current loss in the core. It stays almost constant from no load to full load, so it is a constant loss. Like a KSEB transformer humming even at light load. Recall: is iron loss constant or variable? (Constant)

  6. Fact 6 of 12

    Silicon steel cuts hysteresis loss

    Silicon steel cores have lower hysteresis loss and higher resistivity, so eddy loss also falls. Like choosing a better iron box that wastes less heat. Recall: which steel lowers hysteresis loss? (Silicon steel)

  7. Fact 7 of 12

    Mechanical loss: bearing and brush friction

    Mechanical loss is power used to overcome friction at bearings and brushes. It stays nearly constant at constant speed. Like scooter wheel bearings wasting power even while coasting. Recall: which loss is bearing friction? (Mechanical)

  8. Fact 8 of 12

    Windage loss rises with rotor speed

    Windage is air drag on the spinning rotor, and it grows as speed rises. Faster rotors waste more power against air. Like a ceiling fan on high draining more units than on low. Recall: does windage rise or fall with speed? (Rise)

  9. Fact 9 of 12

    Stray load loss: the 1% convention

    Stray load loss is extra loss under load, from flux distortion and eddy currents in conductors. Standard practice takes it as about 1% of output. Like the small unexplained extra units on a KSEB bill. Recall: stray load loss is usually taken as what percent? (1%)

  10. Fact 10 of 12

    Maximum efficiency: constant equals variable loss

    A DC generator is most efficient when constant losses equal variable losses. Iron plus mechanical loss equals copper loss at that point. Like a bus cruising at the speed where it wastes least fuel. Recall: max efficiency when constant loss equals what? (Variable loss)

  11. Fact 11 of 12

    Generator efficiency formula

    Efficiency = output / input = output / (output + total losses). Total losses = copper + iron + mechanical + stray load. Like comparing units sold with units bought from the grid. Recall: efficiency = output divided by what? (Input)

  12. Fact 12 of 12

    Constant vs variable losses

    Constant losses: iron, mechanical, and shunt field copper. Variable losses: armature copper and stray load. Like a KSEB bill with a fixed charge and a per-unit charge. Recall: is stray load loss constant or variable? (Variable)