QuizKerala

Do you know?

[BOTH] Synchronous machines - part 3

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    V curve: the lowest point is unity power factor

    A V curve plots armature current against field current at constant load. Minimum armature current occurs at unity power factor. Recall: At the V curve minimum, what is the power factor?

  2. Fact 2 of 12

    Under-excited motor draws lagging current

    Less field current makes a synchronous motor draw lagging current, like a house fan or tube light. It absorbs reactive power. Recall: Under-excited means lagging or leading current?

  3. Fact 3 of 12

    Over-excited machine draws leading current

    More field current makes it draw leading current, so it acts like a capacitor and supplies reactive power. Recall: Over-excited gives leading or lagging current?

  4. Fact 4 of 12

    Synchronous condenser: a motor with no load

    A synchronous condenser is an over-excited synchronous motor running on no load. It supplies only reactive power, measured in kVAR. Recall: What load does a synchronous condenser carry?

  5. Fact 5 of 12

    Adjustable VAR, unlike fixed capacitor banks

    Field current smoothly changes a synchronous condenser's reactive power. Substations use this to hold voltage steady. Recall: Which knob changes its kVAR output?

  6. Fact 6 of 12

    Power factor = kW divided by kVA

    Power factor equals kW divided by kVA, which is cos phi. Low power factor draws more current for the same useful power, so losses rise. Recall: Write the power factor formula in plain text.

  7. Fact 7 of 12

    Leading kVAR cancels lagging kVAR

    Lagging reactive power from motors is cancelled by leading kVAR from a synchronous condenser. This is power factor correction. Recall: What is the unit of reactive power?

  8. Fact 8 of 12

    Hunting: rotor swings around synchronous speed

    Hunting is the rotor oscillating about synchronous speed after a sudden load change. It is like a bus swaying after a hard brake. Recall: Another name for hunting?

  9. Fact 9 of 12

    Damper windings stop hunting

    Damper windings, also called amortisseur windings, sit on the rotor poles and damp the swing. They work like a scooter's shock absorber. Recall: What are damper windings also called?

  10. Fact 10 of 12

    Damper winding also starts the motor

    Damper windings give a synchronous motor starting torque, so it can start like an induction motor. Recall: Which winding gives a synchronous motor its starting torque?

  11. Fact 11 of 12

    Engine-driven generators hunt more

    Pulsating torque from diesel engines, like a hospital genset, makes hunting more likely. Weak damping makes it worse. Recall: Name one cause of hunting in few words.

  12. Fact 12 of 12

    Long lines at light load give leading VAR

    At light load, a long transmission line produces excess leading VAR, which raises voltage. An under-excited synchronous condenser absorbs it. Recall: At light load, does a long line give leading or lagging VAR?