  1. Fact 1 of 12

    The gate is the SCR's switch

    An SCR has anode, cathode and gate. A small gate pulse turns the big load ON. Quiz: Which terminal turns the SCR ON? Answer: Gate.

  2. Fact 2 of 12

    SCR stays ON after the pulse

    Once conducting, the SCR keeps conducting even after the gate pulse is removed. Why: the gate only starts conduction, it cannot stop it. Quiz: Does the gate need to stay triggered? Answer: No.

  3. Fact 3 of 12

    Latching current holds it ON

    Latching current is the minimum anode current needed just after triggering. If current stays below it, the SCR turns OFF again. Quiz: Current needed right after triggering? Answer: Latching current.

  4. Fact 4 of 12

    Holding current decides turn-OFF

    Holding current is the minimum anode current needed to keep the SCR conducting. Below it, the SCR switches OFF. Quiz: Below which current does the SCR turn OFF? Answer: Holding current.

  5. Fact 5 of 12

    Gate cannot switch a basic SCR OFF

    A basic SCR cannot be turned OFF by the gate; its anode current must be reduced. Turning a conducting SCR OFF is called commutation. Quiz: Exam word for turning OFF? Answer: Commutation.

  6. Fact 6 of 12

    Mains supply turns SCR OFF itself

    In AC supply, current crosses zero every half cycle, so the SCR turns OFF naturally. This is natural commutation, like the 50 Hz supply at your KSEB meter. Quiz: Name this type. Answer: Natural commutation.

  7. Fact 7 of 12

    Forced commutation needs an LC circuit

    In DC circuits, current has no natural zero crossing, so an LC circuit forces it to zero. This is forced commutation. Quiz: What circuit forces the current to zero? Answer: LC circuit.

  8. Fact 8 of 12

    Controlled rectifier replaces diodes

    A controlled rectifier uses SCRs in place of diodes, so DC output is adjustable. Everyday word: adjustable. Exam word: controlled. Quiz: What replaces diodes here? Answer: SCRs.

  9. Fact 9 of 12

    Firing angle controls DC output

    Firing angle is the delay from the zero crossing to the gate pulse. A bigger delay gives less DC output, with no moving parts. Quiz: Bigger firing angle gives more or less output? Answer: Less.

  10. Fact 10 of 12

    Half-wave controlled rectifier formula

    For half-wave, average DC is Vdc = Vm/(2 pi) x (1 + cos alpha), where Vm is peak voltage and alpha is firing angle. Quiz: Output at alpha = 0? Answer: Vm/pi, maximum.

  11. Fact 11 of 12

    Single-phase full-wave formula

    For single-phase full-wave controlled rectifier, Vdc = (2 x Vm/pi) x cos alpha. Output becomes zero at alpha = 90 degrees. Quiz: Output at alpha = 90 degrees? Answer: Zero.

  12. Fact 12 of 12

    Half-wave firing angle range

    For half-wave, alpha ranges from 0 to 180 degrees. At 180 degrees the output is zero, since the formula gives 1 + cos 180 = 0. Quiz: Maximum firing angle for half-wave? Answer: 180 degrees.