[BOTH] Wiring systems and earthing - part 2

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Concealed wiring hides cables inside walls

    Concealed wiring runs cables inside walls and ceilings, out of sight. Why: it is safe from damage and looks neat. Kerala house: cables hide behind the wall plaster. Q: Where are concealed cables? Answer: inside walls.

  2. Fact 2 of 12

    PVC conduit protects concealed wires

    Concealed wires run through PVC conduit pipes fixed in walls. Why: the pipe guards wires from moisture, nails and rats. Q: What protects concealed wires? Answer: PVC conduit.

  3. Fact 3 of 12

    Conduit makes rewiring easier

    Conduit lets electricians pull wires through for repairs or changes. Why: replacing a wire is quicker. Kerala: adding a fan point later. Q: What helps rewiring? Answer: conduit pipe.

  4. Fact 4 of 12

    Pipe earthing uses a metal pipe in the ground

    Pipe earthing drives a metal GI pipe into the ground as the earth electrode. Why: moist soil around the pipe gives low resistance. Kerala: a common method at home earthing points. Q: Earth electrode that is a metal pipe? Answer: pipe earthing.

  5. Fact 5 of 12

    Plate earthing buries a metal plate in a pit

    Plate earthing buries a metal plate, 60 cm square, in a pit. Why: a wide plate spreads fault current into the earth. Kerala: check the earth pit near your KSEB meter box. Q: Standard plate size? Answer: 60 cm square.

  6. Fact 6 of 12

    Earth wire is green or green-yellow

    Indian colour code makes the earth wire green or green-yellow. Why: anyone can spot it at once and not mistake it for live. Kerala: check the earth wire in your house socket. Q: Earth wire colour? Answer: green.

  7. Fact 7 of 12

    Never fuse or switch the earth wire

    Earth wire must stay continuous, with no fuse or switch on it. Why: a broken earth leaves metal parts live with no safe path. Kerala: a pressure cooker body can give shock. Q: Can earth wire have a switch? Answer: no.

  8. Fact 8 of 12

    Earth wire must carry full fault current

    Earth wire must carry fault current until the MCB or fuse trips. Why: a thin earth wire may burn before the breaker works. Kerala: check earth wire size in your house meter box. Q: What must earth wire carry? Answer: fault current.

  9. Fact 9 of 12

    Ohm's law gives the resistance formula

    Formula: R = V / I. R is resistance in ohms, V voltage in volts, I current in amperes. Why: earth resistance is found this way. Kerala: testers use it when KSEB checks earthing. Q: Formula for resistance? Answer: R = V / I.

  10. Fact 10 of 12

    Ohm is named after Georg Simon Ohm

    The ohm is named after German physicist Georg Simon Ohm. Why: earth resistance is measured in ohms, a common PSC question. Q: Who gave his name to the ohm? Answer: Georg Simon Ohm.

  11. Fact 11 of 12

    Moisture lowers earth resistance

    Dry soil has high resistance, so earth electrodes need moist soil around them. Why: wet soil conducts fault current well. Kerala's monsoon soil helps earthing. Q: What lowers earth resistance? Answer: moisture.

  12. Fact 12 of 12

    Earth tester measures earth resistance

    Earth resistance is measured with an earth tester. Why: a regular test shows whether the earth is still safe. Kerala: ask your electrician to test the earth in your house. Q: Instrument for earth resistance? Answer: earth tester.