[SE] Lighting calculations - part 1

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Utilisation factor: how much light is useful

    Everyday: share of lamp light that reaches the work. Exam: UF = lumens on working plane / lumens emitted. Dark walls absorb light, lowering UF. Recall: What does UF measure? Answer: useful light share.

  2. Fact 2 of 12

    Dark walls waste light

    Dark walls and ceilings absorb light, so UF falls. Reason: reflected light is lost, not sent to the work. Example: a dark-painted bus interior looks dim. Recall: Do dark surfaces raise or lower UF? Answer: lower.

  3. Fact 3 of 12

    Fitting type changes UF

    Direct fittings send most light downward, so UF is higher. Indirect fittings send light up, so UF is lower. Example: a tube light in a KSEB office. Recall: Which fitting gives higher UF? Answer: direct.

  4. Fact 4 of 12

    Room index links room size and height

    Room index K = LW / (H(L+W)), with L length, W width, H height above working plane. Big K gives higher UF. Example: a wide hall with a low ceiling. Recall: What is K called? Answer: room index.

  5. Fact 5 of 12

    Maintenance factor: light lost over time

    Everyday: light fades as lamps age and dust builds up. Exam: maintenance factor (MF) is 1 or less; depreciation factor means the same. Example: a dusty ceiling fan lamp in a Kerala home. Recall: Can MF be more than 1? Answer: no.

  6. Fact 6 of 12

    Lamp lumen depreciation (LLD)

    Lamp lumen depreciation (LLD) is the light drop as a lamp ages. Reason: the lamp's light output falls with use. Example: a tube light in a KSEB office dims after years. Recall: What does LLD measure? Answer: light drop with age.

  7. Fact 7 of 12

    Dust on fittings cuts light

    Luminaire dirt depreciation (LDD) covers dust on fittings. Reason: dust absorbs light before it leaves. Example: a grimy street lamp in a Kerala town. Recall: What lowers light via fitting dust? Answer: LDD.

  8. Fact 8 of 12

    MF is a product of several factors

    In many texts MF = LLMF x LSF x LMF x RSMF. These are lamp lumen, lamp survival, luminaire, and room surface maintenance factors. Example: regular cleaning raises MF. Recall: How many factors multiply? Answer: four.

  9. Fact 9 of 12

    Space to height ratio: spacing vs height

    Everyday: how far apart lights can be. Exam: SHR = spacing between fittings / mounting height above working plane. Reason: spacing keeps light even. Example: ceiling lights in a Kerala school hall. Recall: SHR compares which two distances? Answer: spacing, height.

  10. Fact 10 of 12

    Wide spacing leaves dark patches

    Spacing too large leaves dark patches between fittings. Reason: gaps get too little light. Exam: keep S/H within the maker's limit. Example: bus lights spaced too far apart. Recall: What appears when spacing is too large? Answer: dark patches.

  11. Fact 11 of 12

    Mounting height is measured to the work

    Mounting height is measured from fitting to working plane, not to floor. Reason: the work surface is what needs light. Example: a KSEB office desk lit from the ceiling. Recall: Mounting height is measured to what? Answer: working plane.

  12. Fact 12 of 12

    Low SHR gives even light

    Lower spacing to height ratio gives more even light across the room. Reason: light from neighbouring fittings overlaps. Example: a scooter workshop with bright, even corners. Recall: Low SHR gives what kind of light? Answer: even light.