[SE] Lighting calculations - part 1
- Fact 1 of 12馃挕
Utilisation factor: how much light is useful
Everyday: share of lamp light that reaches the work. Exam: UF = lumens on working plane / lumens emitted. Dark walls absorb light, lowering UF. Recall: What does UF measure? Answer: useful light share.
- Fact 2 of 12馃帹
Dark walls waste light
Dark walls and ceilings absorb light, so UF falls. Reason: reflected light is lost, not sent to the work. Example: a dark-painted bus interior looks dim. Recall: Do dark surfaces raise or lower UF? Answer: lower.
- Fact 3 of 12馃敠
Fitting type changes UF
Direct fittings send most light downward, so UF is higher. Indirect fittings send light up, so UF is lower. Example: a tube light in a KSEB office. Recall: Which fitting gives higher UF? Answer: direct.
- Fact 4 of 12馃搻
Room index links room size and height
Room index K = LW / (H(L+W)), with L length, W width, H height above working plane. Big K gives higher UF. Example: a wide hall with a low ceiling. Recall: What is K called? Answer: room index.
- Fact 5 of 12馃Ч
Maintenance factor: light lost over time
Everyday: light fades as lamps age and dust builds up. Exam: maintenance factor (MF) is 1 or less; depreciation factor means the same. Example: a dusty ceiling fan lamp in a Kerala home. Recall: Can MF be more than 1? Answer: no.
- Fact 6 of 12馃搲
Lamp lumen depreciation (LLD)
Lamp lumen depreciation (LLD) is the light drop as a lamp ages. Reason: the lamp's light output falls with use. Example: a tube light in a KSEB office dims after years. Recall: What does LLD measure? Answer: light drop with age.
- Fact 7 of 12馃Ы
Dust on fittings cuts light
Luminaire dirt depreciation (LDD) covers dust on fittings. Reason: dust absorbs light before it leaves. Example: a grimy street lamp in a Kerala town. Recall: What lowers light via fitting dust? Answer: LDD.
- Fact 8 of 12鉁栵笍
MF is a product of several factors
In many texts MF = LLMF x LSF x LMF x RSMF. These are lamp lumen, lamp survival, luminaire, and room surface maintenance factors. Example: regular cleaning raises MF. Recall: How many factors multiply? Answer: four.
- Fact 9 of 12馃搹
Space to height ratio: spacing vs height
Everyday: how far apart lights can be. Exam: SHR = spacing between fittings / mounting height above working plane. Reason: spacing keeps light even. Example: ceiling lights in a Kerala school hall. Recall: SHR compares which two distances? Answer: spacing, height.
- Fact 10 of 12馃寫
Wide spacing leaves dark patches
Spacing too large leaves dark patches between fittings. Reason: gaps get too little light. Exam: keep S/H within the maker's limit. Example: bus lights spaced too far apart. Recall: What appears when spacing is too large? Answer: dark patches.
- Fact 11 of 12馃彔
Mounting height is measured to the work
Mounting height is measured from fitting to working plane, not to floor. Reason: the work surface is what needs light. Example: a KSEB office desk lit from the ceiling. Recall: Mounting height is measured to what? Answer: working plane.
- Fact 12 of 12鈿栵笍
Low SHR gives even light
Lower spacing to height ratio gives more even light across the room. Reason: light from neighbouring fittings overlaps. Example: a scooter workshop with bright, even corners. Recall: Low SHR gives what kind of light? Answer: even light.