Do you know?
[SE] Bridges and cable fault tests - part 1
- Fact 1 of 12๐งญ
Maxwell bridge measures inductance
Maxwell bridge finds an unknown inductance by balancing it against a known capacitor. Recall: which known component does it use? Answer: capacitor.
- Fact 2 of 12โ๏ธ
Maxwell balance formula
At balance, unknown inductance L = R2 x R3 x C4. Like a balanced scale, the detector reads zero when both sides match. Recall: which bridge uses L = R2 x R3 x C4? Answer: Maxwell.
- Fact 3 of 12๐
Maxwell balance ignores frequency
At balance, the Maxwell bridge does not depend on supply frequency, so one setting works at any frequency. Useful when testing a coil on a workshop bench. Recall: does its balance change with frequency? Answer: no.
- Fact 4 of 12๐
Maxwell suits medium-Q coils
Maxwell bridge works best for coils with medium Q, because high-Q coils need other bridges. Recall: for which coil type is Maxwell bridge suited? Answer: medium-Q.
- Fact 5 of 12๐จโ๐ฌ
Named after James Clerk Maxwell
The Maxwell bridge is named after James Clerk Maxwell, the Scottish physicist. Exam tip: remember the name with the bridge. Recall: who is the Maxwell bridge named after? Answer: James Clerk Maxwell.
- Fact 6 of 12๐
Anderson bridge is a Maxwell variant
Anderson bridge is a modified Maxwell bridge that measures inductance using a standard capacitor. The change gives better accuracy for coils. Recall: Anderson bridge is a modified which bridge? Answer: Maxwell.
- Fact 7 of 12๐
Why Anderson uses a capacitor
Anderson bridge uses a standard capacitor because capacitors are more stable and accurate than standard inductors. Like a reliable meter, it gives a dependable reading. Recall: which standard component does Anderson use? Answer: capacitor.
- Fact 8 of 12๐
Detector shows Anderson balance
Anderson bridge needs an AC supply and a sensitive detector to show balance. Balance is reached when the needle stops at zero, like a meter settling. Recall: what shows balance in Anderson bridge? Answer: detector.
- Fact 9 of 12๐งช
Schering bridge measures capacitance
Schering bridge measures capacitance, mainly of capacitors and insulation samples. It works by balancing against a standard capacitor. Recall: which bridge measures capacitance? Answer: Schering.
- Fact 10 of 12๐
Schering capacitance formula
At balance, unknown capacitance Cx = C3 x R4 / R3, where C3 is the standard capacitor. Like a scale, unknown equals known times a ratio of arms. Recall: which bridge gives Cx = C3 x R4 / R3? Answer: Schering.
- Fact 11 of 12๐ง
Schering finds dielectric loss
At balance, Schering bridge gives loss factor tan delta = omega x C4 x R4. Low loss means good insulation, like a healthy cable. Recall: what does tan delta measure? Answer: dielectric loss.
- Fact 12 of 12โก
Schering tests high-voltage insulation
Schering bridge is used to test high-voltage insulation of power cables and transformer bushings. Like KSEB checking line insulation before a fault, it catches weak insulation early. Recall: what does Schering bridge test? Answer: insulation.