    PID: Proportional, Integral, Derivative

    PID stands for Proportional, Integral and Derivative, the three actions in most industrial controllers. Why: each action fixes a weakness of the others. Recall: name the three PID terms.

  2. Fact 2 of 12

    Proportional action: correct by the gap now

    Output grows with the error, the gap between setpoint and measured value. Like a scooter throttle pressed harder when speed drops. Limit: a small steady offset remains. Recall: what error does P leave?

  3. Fact 3 of 12

    Integral action removes steady offset

    Integral action adds up past error over time, so the steady offset is driven to zero. Like a bus driver who keeps correcting steering until the bus sits centred in its lane. Risk: integral windup. Recall: which action removes offset?

  4. Fact 4 of 12

    Derivative action brakes early

    Derivative action reacts to how fast the error is changing, so it cuts overshoot. Like a bus driver easing off before a speed breaker. Drawback: sensor noise gets amplified. Recall: which action reacts to rate of change?

  5. Fact 5 of 12

    PD controller: fast, but offset stays

    A PD controller has proportional and derivative action but no integral action, so it responds fast yet keeps a steady offset. Used where quick response matters more than exact final value. Recall: what error does PD keep?

  6. Fact 6 of 12

    Ziegler-Nichols tuning dates from 1942

    Ziegler and Nichols published their PID tuning method in 1942. Why it matters: it gives a practical starting point for Kp, Ti and Td from the loop's own response. Recall: which year did Ziegler-Nichols tuning appear?

  7. Fact 7 of 12

    The PID formula in plain text

    Output u = Kp x e + Ki x (integral of e dt) + Kd x (de/dt), with e = setpoint minus measured value. Why: this one line is the whole PID controller. Recall: what is e called?

  8. Fact 8 of 12

    PID units: Ti and Td in seconds

    In time form, Kp is dimensionless, while integral time Ti and derivative time Td are in seconds. Since Ki = Kp/Ti, a bigger Ti means weaker integral action. Recall: unit of Td?

  9. Fact 9 of 12

    PID idea traces to Minorsky, 1922

    Nicolas Minorsky described PID-type control in 1922 while working on automatic ship steering. Why it matters: the idea later moved from ships to factories. Recall: what was the 1922 application?

  10. Fact 10 of 12

    DCS: control spread across one plant

    A DCS, Distributed Control System, spreads control across many local controllers linked to operator stations inside one plant. Why: if one controller fails, the whole plant does not stop. Recall: DCS works inside one what?

  11. Fact 11 of 12

    First commercial DCS: Honeywell TDC 2000, 1975

    Honeywell's TDC 2000, launched in 1975, is widely cited as the first commercial DCS. Why setters ask it: it is a year-and-company question. Recall: which company made TDC 2000?

  12. Fact 12 of 12

    SCADA: supervise many remote sites

    SCADA, Supervisory Control and Data Acquisition, monitors and supervises remote sites spread over a wide area. Kerala example: KSEB grid monitoring of substations, with local controllers doing the actual switching. Recall: what does SCADA stand for?