QuizKerala

Do you know?

[BOTH] Synchronous machines - part 1

11 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 11

    Why the alternator armature stays still

    In an alternator the armature stays still and the field rotates. Why: slip rings carry only small DC field current, not heavy AC output. Recall: which part stays still? (Armature)

  2. Fact 2 of 11

    Big windings fit well in a still frame

    The stator is the stationary part. Its big windings get space, insulation and cooling easily. Why: a fixed frame is easier to build large. Recall: what does stator mean? (Stationary part)

  3. Fact 3 of 11

    Three phases sit 120 degrees apart

    Three stator winding sets are placed 120 electrical degrees apart. Why: their voltages peak one after another, giving smooth three phase power, like KSEB supply wires. Recall: phase spacing? (120 degrees)

  4. Fact 4 of 11

    Salient pole rotor: poles stick out

    A salient pole rotor has poles projecting outward like spokes from a centre. Why: it suits slow, many-pole machines. Used in hydro generators. Recall: which rotor has projecting poles? (Salient pole)

  5. Fact 5 of 11

    Cylindrical rotor: smooth and round

    A cylindrical rotor is smooth and round, with slots for winding. Why: it spins evenly at high speed without big stress. Used in steam turbo generators. Recall: which rotor is smooth? (Cylindrical)

  6. Fact 6 of 11

    Hydro generators turn slowly

    Water turbines turn slowly, so hydro generators have many poles to make 50 Hz. Why: this needs a large diameter, salient pole rotor. Kerala example: Idukki hydro plant. Recall: hydro rotor type? (Salient pole)

  7. Fact 7 of 11

    Turbo generators spin fast

    Steam turbines spin fast, so turbo generators use 2 poles. At 50 Hz they run at 3000 rpm. Why: fast speed needs a cylindrical rotor. Recall: turbo speed at 50 Hz? (3000 rpm)

  8. Fact 8 of 11

    Synchronous speed formula

    Formula: Ns = 120 x f / P. Ns is rpm, f is frequency in Hz, P is number of poles. Why: rotor and field turn in step. Example: 50 Hz, 4 poles gives 1500 rpm. Recall: Ns for 50 Hz, 2 poles? (3000 rpm)

  9. Fact 9 of 11

    Hydro vs turbo: speed decides shape

    Hydro: slow, many poles, salient rotor, large diameter. Turbo: fast, 2 poles, cylindrical rotor, small diameter. Why: speed decides the rotor design. Recall: which is faster? (Turbo)

  10. Fact 10 of 11

    Why round rotors suit high speed

    A round rotor has mass spread evenly around its axis. Why: it vibrates less at high speed, like a balanced bus engine flywheel. Recall: why less vibration? (Even mass)

  11. Fact 11 of 11

    Why power goes straight to the grid

    The stationary armature gives a direct output connection to the grid. Why: no sliding contact carries the main power, like the wires to your KSEB meter. Recall: which winding feeds the grid? (Armature)