[BOTH] Power and energy measurement - part 1

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Dynamometer wattmeter: two coils, one reading

    Current coil sits in series with the load; pressure coil goes across the supply. Deflection shows true power (VI cos phi) on AC or DC. Recall: which coil is in series with the load? (Current coil)

  2. Fact 2 of 12

    Pressure coil: high resistance, low current

    Why: high resistance stops it drawing much current, so it does not disturb the circuit it measures. Recall: pressure coil resistance, high or low? (High)

  3. Fact 3 of 12

    Two wattmeter method: total three-phase power

    Total three-phase power = W1 + W2 for a 3-wire system. Works for balanced and unbalanced loads. Recall: total power formula? (W1 + W2)

  4. Fact 4 of 12

    No neutral wire needed in two-wattmeter method

    Used in 3-phase 3-wire systems, which have no neutral wire. Why: line voltages are measured directly. Recall: is a neutral wire needed? (No)

  5. Fact 5 of 12

    Negative wattmeter reading: reverse the coil

    If one wattmeter reads backwards, reverse its pressure coil and take that reading as negative. Then total = W1 - W2. Recall: fix for a backward reading? (Reverse pressure coil)

  6. Fact 6 of 12

    Power factor angle from two wattmeter readings

    tan phi = root3 x (W1 - W2) / (W1 + W2). Why: power factor comes from two readings, with no separate pf meter needed. Recall: which function gives phi? (Tangent)

  7. Fact 7 of 12

    Single phase power factor = W / (V x I)

    Power factor = watts divided by (volts x amps). A pure resistive load has power factor 1. Recall: power factor of a pure resistor? (One)

  8. Fact 8 of 12

    Three-phase power uses root 3

    Three-phase power = root3 x line volts x line amps x cos phi. Why: root3 (about 1.732) links line values to total power. Recall: three-phase constant? (Root 3)

  9. Fact 9 of 12

    Induction motors run at low power factor

    Motors and tube light chokes are lagging loads with low power factor. Why: more current flows, wasting energy in KSEB lines and cables. Recall: a common lagging load? (Induction motor)

  10. Fact 10 of 12

    kWh: one unit of electrical energy

    1 unit = 1 kWh = 3.6 million joules. Why: your KSEB bill counts energy used, not power. Recall: 1 unit equals how many joules? (3.6 million)

  11. Fact 11 of 12

    Shallenberger developed a practical AC meter

    Oliver Shallenberger developed a practical AC watt-hour meter in 1888. Exam tip: remember the inventor and year together. Recall: who developed the practical AC watt-hour meter? (Shallenberger)

  12. Fact 12 of 12

    Brake magnet controls the meter disc

    Brake magnet opposes the aluminium disc, so disc speed is proportional to power. Why: it stops the disc racing. Recall: part that controls disc speed? (Brake magnet)