QuizKerala

Do you know?

[AE] Control systems: time response - part 2

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Rise time: how fast the output first reaches target

    Rise time (tr) is how fast the output first reaches its final value. Like an autorickshaw picking up to cruising speed. Recall: unit of rise time? Seconds.

  2. Fact 2 of 12

    Rise time formula for underdamped system

    tr = (π − β)/ωd, where β = arccos ζ and ωd = ωn√(1−ζ²). Exam word: rise time. Recall: what is β? arccos ζ.

  3. Fact 3 of 12

    Peak time: when the first peak comes

    Peak time (tp) is the time to reach the first peak. Formula: tp = π/ωd. Like a scooter's first wobble after a speed bump. Recall: peak time formula? π/ωd.

  4. Fact 4 of 12

    Damped frequency ωd

    ωd = ωn√(1−ζ²) is the frequency of the damped oscillation. It is lower than ωn when ζ is between 0 and 1. Recall: ωd equals ωn times what? √(1−ζ²).

  5. Fact 5 of 12

    Settling time with 2% band

    Settling time (ts) is when the response stays within ±2% of final value. Formula: ts = 4/(ζωn). Recall: 2% settling formula? 4/(ζωn).

  6. Fact 6 of 12

    Settling time with 5% band

    With a ±5% band, ts = 3/(ζωn). Like a KSEB meter needle that stops swinging inside a small band. Recall: 5% settling formula? 3/(ζωn).

  7. Fact 7 of 12

    Why settling depends on ζωn

    The wobble envelope decays as e^(−ζωn·t), so ζωn sets how fast oscillations die. Bigger ζωn means quicker settling. Recall: which product sets settling? ζωn.

  8. Fact 8 of 12

    Higher ωn means faster rise

    Higher natural frequency ωn gives shorter rise and peak times, since they scale with 1/ωn. Like a light scooter speeding up faster than a loaded one. Recall: does rise time go up or down as ωn rises? Down.

  9. Fact 9 of 12

    Rise time: 0–100% or 10–90%?

    For underdamped systems, rise time is often taken from 0 to 100% of final value. For overdamped systems, 10% to 90% is used. Recall: which band for overdamped? 10% to 90%.

  10. Fact 10 of 12

    More damping makes rise slower

    For fixed ωn, a higher damping ratio ζ increases rise time, while reducing overshoot. Like a heavy door closer that shuts slowly. Recall: higher ζ does what to rise time? Increases.

  11. Fact 11 of 12

    Units of time-response terms

    Rise, peak and settling times are in seconds. ωn and ωd are in rad/s, and ζ has no unit. Recall: unit of ζ? None, it is dimensionless.

  12. Fact 12 of 12

    Time-domain specifications

    Rise, peak and settling times are called time-domain specifications, read from the unit step response. Like testing a KSEB meter with a sudden load. Recall: exam name for these? Time-domain specifications.