Do you know?
[AE] Series and parallel magnetic circuits - part 1
- Fact 1 of 10๐งฒ
Series circuit: flux stays the same
In a series magnetic circuit, the same flux passes through every part, like current in a series wire. Recall: what stays the same in series, flux or MMF? Answer: flux.
- Fact 2 of 10โ
Series circuit: MMF adds up
Total MMF is shared across the parts: NI = H1 x l1 + H2 x l2. Each part needs its own share to drive the flux. Recall: which quantity adds up in series? Answer: MMF.
- Fact 3 of 10๐
Series reluctance adds like resistance
For series parts, total reluctance S = S1 + S2 + S3, where S = l / (mu x A). Like series resistors, the sum limits the flux. Recall: how does series reluctance combine? Answer: by sum.
- Fact 4 of 10๐
Parallel branches: MMF is common
In parallel paths the MMF across each branch is the same. Flux splits inversely with reluctance, like current in parallel resistors. Recall: which quantity is common in parallel, flux or MMF? Answer: MMF.
- Fact 5 of 10๐ณ๏ธ
A tiny air gap, a big reluctance
Air has far higher reluctance than iron, so even a small gap can dominate the circuit and cut the flux sharply. The gap sits in series with the iron. Recall: which part dominates a gapped core, iron or air? Answer: air.
- Fact 6 of 10๐ฌ๏ธ
Fringing: flux spreads at the gap
Flux bulges outward at an air gap, so its effective area is larger than the core area. Designers must allow for this when calculating the gap. Recall: what is the outward bulging of flux at a gap called? Answer: fringing.
- Fact 7 of 10๐
PSC units: MMF, flux and reluctance
MMF is in ampere-turns (AT), flux in weber (Wb), and reluctance in AT/Wb. Reluctance = MMF / flux, the magnetic analogue of Ohm's law. Recall: what is the unit of reluctance? Answer: AT/Wb.
- Fact 8 of 10๐
Leakage flux: flux that escapes
Leakage flux links only one winding and does not complete the core path to the other winding. It is wasted flux that weakens coupling between windings. Recall: what is flux linking only one winding called? Answer: leakage flux.
- Fact 9 of 10โ
Total flux splits into two parts
Total flux equals mutual flux plus leakage flux: Phi = Phi_m + Phi_l. Only the mutual flux transfers energy between windings. Recall: which flux transfers energy between windings? Answer: mutual flux.
- Fact 10 of 10๐ ๏ธ
Reduce leakage with interleaved windings
Interleaving primary and secondary windings keeps leakage flux low, because more flux links both windings. Lower leakage means better coupling and smaller voltage drop. Recall: what winding layout reduces leakage flux? Answer: interleaved windings.