Do you know?
[AE] Control systems: time response - part 3
- Fact 1 of 12馃殞
Overshoot: going past the target
Overshoot means the output goes past its final value, like an autorickshaw rolling past the stand. Exam form: Mp = 100 x exp(-pi x zeta / sqrt(1 - zeta^2)) percent. Recall: what is overshoot?
- Fact 2 of 12馃浀
More damping, less overshoot
Higher damping ratio zeta gives less overshoot, like a scooter's shock absorber stopping the bounce. Zeta of 1 or more gives zero overshoot. Recall: which zeta gives zero overshoot?
- Fact 3 of 12馃幆
Steady state error: the final gap
Steady state error is the difference left between input and output after the transient dies out, like a KSEB meter that settles short of the true reading. Recall: what is steady state error?
- Fact 4 of 12馃М
Unity feedback error formula
For unity feedback, e_ss = lim s->0 of s R(s) / (1 + G(s)), where R(s) is the input and G(s) the forward path. Recall: which term sets the final error?
- Fact 5 of 12馃搷
Kp: position error constant
Kp is the position error constant, Kp = lim s->0 of G(s), and it has no unit. A larger Kp means a smaller error for step input. Recall: which constant is for step input?
- Fact 6 of 12馃獪
Step error = 1/(1+Kp)
For a type 0 system, step error e_ss = 1/(1+Kp), so the error stays finite. A type 1 or higher system has zero step error. Recall: step error of a type 1 system?
- Fact 7 of 12馃弮
Kv: velocity error constant
Kv is the velocity error constant, Kv = lim s->0 of s G(s), measured per second. It decides error for a ramp input, like a bus gaining speed steadily. Recall: which input does Kv handle?
- Fact 8 of 12馃搱
Ramp error = 1/Kv
For a ramp input, a type 1 system has steady state error 1/Kv, and a type 2 or higher system has zero ramp error. Recall: ramp error of a type 2 system?
- Fact 9 of 12馃殌
Ka: acceleration error constant
Ka is the acceleration error constant, Ka = lim s->0 of s^2 G(s), measured per second squared. It decides error for a parabolic input. Recall: which input does Ka handle?
- Fact 10 of 12馃搻
Parabolic error = 1/Ka
For a parabolic input, a type 2 system has steady state error 1/Ka, while type 0 and type 1 systems have infinite error. Recall: parabolic error of a type 1 system?
- Fact 11 of 12馃敘
Type counts integrators
The type of a system is the number of pure integrators, that is poles at s = 0, in the forward path G(s). The type decides which error constant is finite. Recall: what does type count?
- Fact 12 of 12馃搹
Units of the three constants
Kp is dimensionless, Kv is per second, and Ka is per second squared. PSC questions often ask these units as options. Recall: which constant is dimensionless?