  1. Fact 1 of 12

    Steady state stability: small, slow changes

    Steady state stability means generators stay in step after small, slow load changes, like a bus holding speed on a gentle slope. Recall: which stability covers small, slow load changes?

  2. Fact 2 of 12

    Steady state limit is at 90 degrees

    Power transfer peaks at delta = 90 degrees, and beyond that the system loses steady state stability because more angle gives less holding power. Recall: at what angle is the steady state limit?

  3. Fact 3 of 12

    Power angle formula: P = EV sin delta / X

    In P = EV sin delta / X, P is power, E and V are voltages, X is reactance in ohms, and delta is the power angle. Recall: in what unit is X measured?

  4. Fact 4 of 12

    Maximum power is EV divided by X

    At delta = 90 degrees, sin delta is 1, so P max = EV/X, and lower reactance lets more power flow. Recall: what is P max in terms of E, V and X?

  5. Fact 5 of 12

    Transient stability: big sudden faults

    Transient stability is the ability to stay in step after a large sudden disturbance, like a short circuit on a line. Recall: which stability deals with a line short circuit?

  6. Fact 6 of 12

    Critical clearing time limits a fault

    Critical clearing time is the longest a fault can last before generators lose synchronism, so faster breakers help. Recall: what is the longest safe fault time called?

  7. Fact 7 of 12

    Equal area criterion checks transient stability

    The equal area criterion compares accelerating and decelerating energy areas on the power angle curve to judge transient stability. Recall: which curve does the equal area criterion use?

  8. Fact 8 of 12

    Dynamic stability: oscillations must die out

    Dynamic stability means oscillations after a disturbance settle down over time, like a scooter wobble fading after a bump. Recall: what must oscillations do for dynamic stability?

  9. Fact 9 of 12

    Power system stabilizer adds damping

    A power system stabilizer (PSS) adds damping to generator oscillations, which improves dynamic stability. Recall: which device adds damping to oscillations?

  10. Fact 10 of 12

    Swing equation: accelerating power

    The swing equation is M d2delta/dt2 = Pm minus Pe, where M is inertia, Pm is mechanical input and Pe is electrical output. Recall: what does Pm minus Pe give?

  11. Fact 11 of 12

    Why keep a margin below 90 degrees

    Operating near 90 degrees leaves no reserve, so a small load jump can cause instability, like riding uphill at full effort. Recall: what angle leaves no safety margin?

  12. Fact 12 of 12

    Loss of synchronism means falling out of step

    When generators fall out of step, the system loses synchronism and can black out, like a bus convoy splitting apart. Recall: what is the term for falling out of step?