Do you know?
[AE] Power system stability and load flow - part 1
- Fact 1 of 12โ๏ธ
Steady state stability: small, slow changes
Steady state stability means generators stay in step after small, slow load changes, like a bus holding speed on a gentle slope. Recall: which stability covers small, slow load changes?
- Fact 2 of 12โฐ๏ธ
Steady state limit is at 90 degrees
Power transfer peaks at delta = 90 degrees, and beyond that the system loses steady state stability because more angle gives less holding power. Recall: at what angle is the steady state limit?
- Fact 3 of 12๐
Power angle formula: P = EV sin delta / X
In P = EV sin delta / X, P is power, E and V are voltages, X is reactance in ohms, and delta is the power angle. Recall: in what unit is X measured?
- Fact 4 of 12๐บ
Maximum power is EV divided by X
At delta = 90 degrees, sin delta is 1, so P max = EV/X, and lower reactance lets more power flow. Recall: what is P max in terms of E, V and X?
- Fact 5 of 12๐ฅ
Transient stability: big sudden faults
Transient stability is the ability to stay in step after a large sudden disturbance, like a short circuit on a line. Recall: which stability deals with a line short circuit?
- Fact 6 of 12โฑ๏ธ
Critical clearing time limits a fault
Critical clearing time is the longest a fault can last before generators lose synchronism, so faster breakers help. Recall: what is the longest safe fault time called?
- Fact 7 of 12๐
Equal area criterion checks transient stability
The equal area criterion compares accelerating and decelerating energy areas on the power angle curve to judge transient stability. Recall: which curve does the equal area criterion use?
- Fact 8 of 12๐ต
Dynamic stability: oscillations must die out
Dynamic stability means oscillations after a disturbance settle down over time, like a scooter wobble fading after a bump. Recall: what must oscillations do for dynamic stability?
- Fact 9 of 12๐๏ธ
Power system stabilizer adds damping
A power system stabilizer (PSS) adds damping to generator oscillations, which improves dynamic stability. Recall: which device adds damping to oscillations?
- Fact 10 of 12๐งฎ
Swing equation: accelerating power
The swing equation is M d2delta/dt2 = Pm minus Pe, where M is inertia, Pm is mechanical input and Pe is electrical output. Recall: what does Pm minus Pe give?
- Fact 11 of 12๐ฒ
Why keep a margin below 90 degrees
Operating near 90 degrees leaves no reserve, so a small load jump can cause instability, like riding uphill at full effort. Recall: what angle leaves no safety margin?
- Fact 12 of 12๐
Loss of synchronism means falling out of step
When generators fall out of step, the system loses synchronism and can black out, like a bus convoy splitting apart. Recall: what is the term for falling out of step?