[AE] Star-delta transformation and AC fundamentals - part 1
- Fact 1 of 12🔌
Star connection: line voltage is √3 × phase voltage
In star connection, line voltage VL = √3 × Vph, and line current IL = Iph. Why: the phase ends meet at one common point. Kerala example: the 3-phase pump motor at home. Recall: In star, VL equals √3 times what?
- Fact 2 of 12⚡
Delta connection: line current is √3 × phase current
In delta connection, line voltage VL = Vph, and line current IL = √3 × Iph. Why: current splits at each corner of the triangle. Recall: In delta, IL equals √3 times what?
- Fact 3 of 12✖️
Star to delta: multiply impedance by 3
To convert a star impedance to delta, multiply it by 3 (ZΔ = 3 × ZY). Why: both networks must draw the same current at the same terminals. Recall: Star to delta, multiply impedance by what?
- Fact 4 of 12➗
Delta to star: divide impedance by 3
To convert a delta impedance to star, divide it by 3 (ZY = ZΔ / 3). It is the reverse of star-to-delta conversion. Recall: Delta to star, divide impedance by what?
- Fact 5 of 12🚰
Star-delta starter cuts starting current to one-third
A star-delta starter lowers starting current to one-third of direct-on-line starting. Why: in star, each winding gets 1/√3 of line voltage. Kerala example: borewell and water pump motors. Recall: Starter cuts starting current to what fraction?
- Fact 6 of 12🔄
Star starting torque is one-third of delta
Starting torque in star connection is one-third of the torque in delta. Why: torque depends on the square of voltage, and star gives 1/√3 of voltage per winding. Recall: Star starting torque is what fraction of delta?
- Fact 7 of 12🔀
Star-delta starter: star first, delta later
A star-delta starter connects the motor in star to start, then switches to delta to run. Why: low starting current protects the supply from a sudden dip. Recall: Which connection is used first, star or delta?
- Fact 8 of 12💡
Star draws one-third the power of delta
At the same line voltage, a star-connected load takes one-third the power of the same load in delta. Why: each star winding gets 1/√3 of the line voltage. Recall: Star power is what fraction of delta power?
- Fact 9 of 12📈
RMS of a sine wave is 0.707 times peak
For a sine wave, RMS = 0.707 × Vm, which is Vm divided by √2. Why: RMS gives the same heating effect as DC of that value. Kerala example: 230 V mains is RMS, with peak about 325 V. Recall: Sine RMS equals what times peak?
- Fact 10 of 12📊
Half-cycle average of a sine wave is 0.637 Vm
Average of a half sine cycle is 0.637 × Vm, which is 2Vm divided by π. Why: a full cycle averages to zero because its positive and negative halves cancel. Recall: Half-cycle average equals what times Vm?
- Fact 11 of 12🔋
Half-wave gives 0.318 Vm, full-wave gives 0.637 Vm
A half-wave rectifier gives average 0.318 × Vm, while a full-wave rectifier gives 0.637 × Vm. Why: full-wave uses both halves of the cycle. Kerala example: scooter and car battery chargers. Recall: Full-wave average is what times Vm?
- Fact 12 of 12📐
Form factor of a sine wave is 1.11
Form factor is RMS divided by average, so for a sine wave it is 0.707 ÷ 0.637, which is about 1.11. Why: it shows how flat or peaky a wave is. Recall: Sine wave form factor is about what number?