QuizKerala

Do you know?

[SE] Bridges and cable fault tests - part 2

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Murray loop: finding an earth fault

    Murray loop finds an earth fault by balancing a Wheatstone bridge, like a shop scale at Kochi market. Recall: which bridge finds earth faults? (Answer: Wheatstone)

  2. Fact 2 of 12

    Varley loop: short between two cores

    Varley loop finds a short circuit between two cores, not an earth fault, like two scooter wires touching by mistake. Recall: which fault does Varley loop find? (Answer: short between cores)

  3. Fact 3 of 12

    Varley loop forms at the far end

    In a Varley loop the far ends of the two faulty cores are joined to make a loop for measurement, like a linesman joining two wires to test. Recall: what forms the loop? (Answer: far ends joined)

  4. Fact 4 of 12

    Varley loop is named after a person

    The Varley loop is named after Cromwell Fleetwood Varley, a British telegraph engineer, so exam questions may ask who gave the test its name. Recall: who gave his name to the Varley loop? (Answer: Cromwell Varley)

  5. Fact 5 of 12

    Healthy core must match

    Murray loop needs a healthy core of same length and cross-section, so both paths have equal resistance per metre, like matched tyres on a scooter. Recall: what must the healthy core match? (Answer: length and cross-section)

  6. Fact 6 of 12

    Switch supply off first

    Always switch off supply and disconnect the cable before any loop test, like pulling the plug on a pressure cooker before opening it. Recall: supply on or off during a loop test? (Answer: off)

  7. Fact 7 of 12

    Low fault resistance gives better balance

    Loop tests work best when fault resistance is low, because high fault resistance weakens the galvanometer balance, like a weak autorickshaw horn in traffic. Recall: low or high fault resistance is better? (Answer: low)

  8. Fact 8 of 12

    Fault distance from the balance point

    In Murray loop the fault distance is read from the balance point on the slide wire, and it is proportional to cable length, like counting bus stops from the start. Recall: what gives the fault distance? (Answer: balance point on slide wire)

  9. Fact 9 of 12

    Zero reading means balanced

    The galvanometer reads zero at balance, called the null point, because it is a sensitive current detector, like a KSEB meter needle stopping exactly on zero. Recall: what does a zero galvanometer reading mean? (Answer: bridge balanced)

  10. Fact 10 of 12

    Loop resistance is in ohms

    Loop resistance is measured in ohms (ฮฉ), so fault and healthy core resistances are compared in the same unit, like fares on a bus chart. Recall: unit of loop resistance? (Answer: ohm)

  11. Fact 11 of 12

    Who invented the Wheatstone bridge

    The Wheatstone bridge was invented by Samuel Hunter Christie in 1833 and popularised by Charles Wheatstone, like a Kerala recipe known by a later cook's name. Recall: who invented the bridge? (Answer: Samuel Hunter Christie)

  12. Fact 12 of 12

    Cable must be uniform

    Loop tests assume uniform cable with the same resistance per metre along its length, or the distance reading is wrong, like a bus route with equal stop spacing. Recall: what must the cable be along its length? (Answer: uniform)