Do you know?
[BOTH] Three phase induction motor - part 2
- Fact 1 of 12🔄
Rotor frequency = s × f
Rotor frequency = s × f. Here s is slip (the speed gap) and f is supply frequency, 50 Hz in Kerala. At start s = 1, so rotor frequency = 50 Hz. Recall: Rotor frequency at start? (50 Hz)
- Fact 2 of 12📉
Rotor frequency drops as speed rises
As the motor speeds up, slip falls, so rotor frequency falls. Near full speed it is only a few hertz. Like a home pump motor running near its rated speed. Recall: Rotor frequency at full speed? (Low, few Hz)
- Fact 3 of 12📈
Torque-slip curve rises then falls
Torque rises as slip increases, peaks, then falls. The peak is maximum torque, also called breakdown torque. Beyond the peak the motor stalls, like a bus engine overloaded on a hill. Recall: Name of the peak torque? (Breakdown torque)
- Fact 4 of 12🚀
Starting torque is at slip = 1
At standstill slip is 1, the starting point of the torque-slip curve. The torque here is the starting torque. A pump motor that hums but does not start has weak starting torque. Recall: Slip at standstill? (1)
- Fact 5 of 12⚙️
Max torque when R2 = s X2
Maximum torque occurs when R2 = s X2, where R2 is rotor resistance and X2 is rotor reactance per phase. This is the limit before a motor stalls. Recall: Max torque condition? (R2 = sX2)
- Fact 6 of 12🎯
Slip at maximum torque: s = R2/X2
At maximum torque, slip s = R2 / X2. A motor with higher rotor resistance reaches its peak at a higher slip. Recall: Slip at max torque formula? (R2/X2)
- Fact 7 of 12🧱
Peak torque does not depend on R2
Maximum torque value stays the same whatever the rotor resistance. Rotor resistance only shifts the peak to a different slip. Like changing a fan's wire resistance moves the peak, not its height. Recall: Does R2 change peak torque? (No)
- Fact 8 of 12🔌
DOL means full voltage start
DOL means direct-on-line: full supply voltage is applied at once. Starting current is about 5 to 7 times full-load current. Simple and cheap, so used for small motors. Recall: DOL starting current? (5 to 7 times full load)
- Fact 9 of 12⭐
Star-delta cuts starting current to one-third
Star-delta start connects the stator in star first, then changes to delta. Starting line current and torque both drop to one-third of DOL values. Needs a motor wound for delta running. Recall: Star-delta torque ratio? (One-third)
- Fact 10 of 12🔧
Autotransformer uses tap ratio k
Autotransformer start gives reduced voltage through a tap of 50, 65 or 80 percent. Starting torque and line current become k squared times DOL values, where k is the tap ratio. Used for large mill motors. Recall: Torque ratio with 50 percent tap? (One quarter)
- Fact 11 of 12🧲
Slip-ring motor uses rotor resistance start
Slip-ring motors add external resistance in the rotor circuit during start. This raises starting torque and lowers starting current. The resistance is removed as the motor speeds up, as in lifts and cranes. Recall: Which motor uses rotor resistance start? (Slip-ring)
- Fact 12 of 12🧠
Cage motors cannot use rotor resistance
Squirrel cage rotor has no accessible winding, so external resistance cannot be added. Cage motors use DOL, star-delta or autotransformer start. Recall: Cage motor starting methods? (DOL, star-delta, autotransformer)