[SE] Overhead lines: sag, conductors, supports - part 1

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    ACSR: Aluminium Conductor Steel Reinforced

    ACSR uses aluminium strands to carry current and a steel core to take the weight, like rebar inside a concrete pillar. Recall: what does the steel core give? (Strength)

  2. Fact 2 of 12

    AAC: All Aluminium Conductor

    AAC has no steel core, so it is light and cheap but less strong, suiting short urban spans like an aluminium vessel that bends easily. Recall: what metal is AAC made of? (Aluminium)

  3. Fact 3 of 12

    AAAC: All Aluminium Alloy Conductor

    AAAC uses aluminium alloy, giving more strength than AAC and good corrosion resistance, useful in Kerala's humid coastal belt. Recall: AAAC differs from AAC by using what? (Alloy)

  4. Fact 4 of 12

    Sag formula: S = wLยฒ/8T

    Sag S = wLยฒ/8T, where w is weight per metre (N/m), L is span (m) and T is tension (N). Recall: sag rises with the square of what? (Span)

  5. Fact 5 of 12

    Doubling span makes sag four times bigger

    Sag depends on L squared, so doubling the span makes sag four times as large, like a clothesline sagging between two far poles. Recall: doubling span multiplies sag by how much? (Four)

  6. Fact 6 of 12

    Higher tension means less sag

    Sag is inversely proportional to tension T, so pulling the line tighter reduces droop, like tightening a clothesline. Recall: what reduces sag? (Higher tension)

  7. Fact 7 of 12

    Hot summer makes lines sag more

    Conductors expand when hot, so sag increases on a summer afternoon, which is why clearance is checked for the hottest day. Recall: what does heat do to sag? (Increases it)

  8. Fact 8 of 12

    Monsoon wind adds load to the line

    Wind pressure adds to the effective weight per metre w, so the conductor sags more during monsoon gusts, like a wet cloth pulling a line down. Recall: which monsoon factor adds load? (Wind)

  9. Fact 9 of 12

    ACSR is written as 6/1 stranding

    A common ACSR size like 6/1 means 6 aluminium strands wound around 1 steel core. Recall: in 6/1, how many steel strands? (One)

  10. Fact 10 of 12

    Why aluminium, not copper, for overhead lines

    Aluminium is much lighter than copper, about a third of its density, so the line carries less weight and sags less. Recall: why prefer aluminium for overhead lines? (Lighter)

  11. Fact 11 of 12

    Galvanised steel core resists rust

    The steel core of ACSR is galvanised, meaning coated with zinc, so it resists rust and keeps its strength for years. Recall: what coating protects the steel core? (Zinc)

  12. Fact 12 of 12

    Keep ground clearance above the road

    Sag is designed so the conductor stays above roads, houses and buses even on the hottest day, which is why the lowest point matters. Recall: what must the line keep above ground? (Clearance)