[BOTH] Transformer principle and EMF equation - part 1

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Mutual induction: the basic idea

    A changing current in one coil induces EMF in a nearby second coil, with no wire joining them. Why: the changing flux links both coils. Recall: What links the two coils? (Magnetic flux)

  2. Fact 2 of 12

    Transformers need AC, not DC

    A transformer works only on AC, because the flux must keep changing. Steady DC gives steady flux, so no EMF is induced. Recall: Which supply does a transformer need? (AC)

  3. Fact 3 of 12

    Faraday discovered induction in 1831

    Michael Faraday discovered electromagnetic induction in 1831. Every transformer uses this same principle. Recall: Who discovered electromagnetic induction, and in which year? (Faraday, 1831)

  4. Fact 4 of 12

    The EMF equation

    EMF E = 4.44 x f x N x ฮฆm (RMS value). E is in volts, f in hertz, N is turns, and ฮฆm is peak flux in weber. Recall: Which symbol is the peak flux? (ฮฆm)

  5. Fact 5 of 12

    Where does 4.44 come from?

    The constant 4.44 is approximately 2ฯ€ divided by the square root of 2. It comes from the sine-wave shape of AC. Recall: What is 4.44 approximately equal to? (2ฯ€/โˆš2)

  6. Fact 6 of 12

    Kerala supply frequency: 50 Hz

    Kerala mains supply is 50 Hz, so f = 50 in the EMF equation for KSEB transformers. Why: more cycles per second means more flux change. Recall: Kerala mains frequency? (50 Hz)

  7. Fact 7 of 12

    More turns, more EMF

    For the same flux and frequency, more turns N gives more EMF in that coil. Why: each turn adds its own induced voltage. Recall: Which symbol is number of turns? (N)

  8. Fact 8 of 12

    Weber: the unit of flux

    Magnetic flux ฮฆ is measured in weber (Wb). One weber equals one volt-second. Recall: What is the SI unit of magnetic flux? (Weber)

  9. Fact 9 of 12

    The turns ratio

    In an ideal transformer, E1 / E2 = N1 / N2. The voltage ratio equals the turns ratio. Recall: Voltage ratio equals what ratio? (Turns ratio)

  10. Fact 10 of 12

    Step-up and step-down

    If secondary turns N2 are more than primary N1, voltage steps up. Long lines carry high voltage to cut losses. Recall: Step-up means N2 is more or less than N1? (More)

  11. Fact 11 of 12

    Current runs opposite to voltage

    In an ideal transformer, V1/V2 = I2/I1. A step-up raises voltage and lowers current, with power the same. Recall: In a step-up, does current go up or down? (Down)

  12. Fact 12 of 12

    Why transformers are rated in kVA

    Transformers are rated in kVA, not kW, because copper and iron losses depend on voltage and current only. Recall: Unit used for transformer rating? (kVA)