    Fuse: the wire that sacrifices itself

    A fuse is a thin wire that melts when current exceeds its rating, breaking the circuit before wires overheat. Kerala example: an iron and a rice cooker on one socket can blow the fuse. Recall: what melts to protect wiring? Answer: fuse.

  2. Fact 2 of 12

    MCB: the resettable circuit breaker

    An MCB, miniature circuit breaker, trips on overload or short circuit and can be switched back on after tripping. Kerala example: a shop's MCB trips when fans, fridge and lights run together. Recall: can an MCB be reused after tripping? Answer: yes.

  3. Fact 3 of 12

    Inside an MCB: two trip mechanisms

    A bimetal strip bends slowly on overload, while an electromagnet trips the MCB instantly on short circuit. Heat is slow, but a short circuit needs instant action. Recall: which part handles short circuit? Answer: electromagnet.

  4. Fact 4 of 12

    RCCB: the 30 mA life saver

    An RCCB trips when live and neutral currents differ by 30 mA, cutting power to protect people from shock. Formula: leakage current = live current minus neutral current. Recall: what does an RCCB sense? Answer: current imbalance.

  5. Fact 5 of 12

    ELCB senses voltage on the earth wire

    An ELCB, earth leakage circuit breaker, is the older type that works through the earth wire, so it needs a proper earth to operate. Kerala example: an ELCB will not protect well in a house with a broken earth. Recall: what does an ELCB need to work? Answer: earth wire.

  6. Fact 6 of 12

    RCCB vs ELCB: the key exam difference

    An RCCB senses current imbalance and does not depend on the earth wire, while an ELCB depends on earth. Why it matters: RCCB is the modern choice for homes. Recall: which device senses current imbalance? Answer: RCCB.

  7. Fact 7 of 12

    Test your RCCB every month

    Press the test button on an RCCB monthly; it should trip immediately, proving it works. Kerala example: a wet-kitchen pump circuit may be protected only if its RCCB trips when tested. Recall: how often should the RCCB test button be pressed? Answer: monthly.

  8. Fact 8 of 12

    Indian colour code: live is red

    In standard Indian single-phase house wiring, live is red, neutral is black and earth is green. Why it matters: correct colours tell electricians which wire is dangerous. Recall: which wire carries live current in a house? Answer: red.

  9. Fact 9 of 12

    Three-phase colours: red, yellow, blue

    In three-phase wiring the three phases are red, yellow and blue, with black as neutral. Kerala example: a KSEB three-phase meter connection uses these colours. Recall: name the three phase colours. Answer: red, yellow, blue.

  10. Fact 10 of 12

    Earth wire: green, never switched

    The earth wire is green, or green-yellow, and must never be fused or switched off. Why it matters: it carries fault current safely to earth. Recall: what colour is the earth wire in Indian wiring? Answer: green.

  11. Fact 11 of 12

    Never replace a fuse with copper wire

    A blown fuse must be replaced with one of the same rating, never with copper wire, because copper will not melt and protect the circuit. Kerala example: a bulb holder fuse replaced with a nail is a fire risk. Recall: what must a fuse replacement match? Answer: rating.

  12. Fact 12 of 12

    Current from power: I = P / V

    Current equals power divided by voltage, I = P / V, and Kerala homes use 230 V single phase. A 1000 W iron draws about 4.3 A, which helps choose the right MCB or fuse. Recall: what is the formula for current? Answer: I = P / V.