Do you know?
[BOTH] DC motor principle and speed control - part 3
- Fact 1 of 12๐ง
Below base speed: control armature voltage
Keep the field full and lower the armature voltage to slow the motor. Speed N = (V - Ia x Ra) / (K x phi). Torque stays constant, which suits lathes. Recall: which control is used below base speed?
- Fact 2 of 12โก
Above base speed: weaken the field
Reduce the field flux and the speed rises. N is proportional to 1/phi. Torque falls as flux falls, so power stays roughly constant. Recall: which control gives speed above base?
- Fact 3 of 12๐
What is base speed?
Base speed is the rated speed at rated armature voltage and full field. Below it, use voltage control. Above it, use field control. Recall: at what field strength is base speed reached?
- Fact 4 of 12๐จ
Never open the shunt field circuit
With the field off, flux nearly vanishes and speed races upward, a runaway that can wreck the motor. The field must be energised before the armature. Recall: what happens if the shunt field opens?
- Fact 5 of 12๐
Why a DC motor needs a starter
At standstill, back EMF is zero, so Ia = V / Ra becomes very large and can burn the armature. A starter adds resistance that is cut out as speed rises. Recall: what is zero at standstill?
- Fact 6 of 12๐
Back EMF limits armature current
Back EMF Eb = V - Ia x Ra. It grows with speed, so armature current falls as the motor speeds up. Recall: which quantity grows with speed and limits current?
- Fact 7 of 12๐
3-point starter: for shunt motors
It has three terminals: L (line), A (armature) and F (field). It carries a no-volt coil and an overload release. Used for shunt motors. Recall: which motor uses a 3-point starter?
- Fact 8 of 12๐งฒ
4-point starter: for compound motors
It has a fourth terminal for the series field, so the series and shunt fields are both connected. Used for compound motors. Recall: which motor uses a 4-point starter?
- Fact 9 of 12๐งท
No-volt coil stops runaway on power cut
It holds the starter handle ON while supply is available. If power fails, a spring returns the handle to OFF, protecting the motor. Recall: what returns the handle to OFF on power failure?
- Fact 10 of 12๐ก๏ธ
Overload release trips on heavy load
It is in series with the armature. When current exceeds the safe limit it trips and cuts the supply. Recall: which starter part protects against overload current?
- Fact 11 of 12๐
Start gently, like a Kerala bus
A bus pulls away gently from a stop instead of jerking. A starter works the same way, letting current build up safely as the motor gathers speed. Recall: what does a starter limit at start?
- Fact 12 of 12๐ฅ
Armature control wastes power as heat
Losses in the series rheostat are I squared R, so efficiency drops at low speed. Electronic drives reduce this loss. Recall: which loss rises in the series rheostat?