  1. Fact 1 of 12

    Below base speed: control armature voltage

    Keep the field full and lower the armature voltage to slow the motor. Speed N = (V - Ia x Ra) / (K x phi). Torque stays constant, which suits lathes. Recall: which control is used below base speed?

  2. Fact 2 of 12

    Above base speed: weaken the field

    Reduce the field flux and the speed rises. N is proportional to 1/phi. Torque falls as flux falls, so power stays roughly constant. Recall: which control gives speed above base?

  3. Fact 3 of 12

    What is base speed?

    Base speed is the rated speed at rated armature voltage and full field. Below it, use voltage control. Above it, use field control. Recall: at what field strength is base speed reached?

  4. Fact 4 of 12

    Never open the shunt field circuit

    With the field off, flux nearly vanishes and speed races upward, a runaway that can wreck the motor. The field must be energised before the armature. Recall: what happens if the shunt field opens?

  5. Fact 5 of 12

    Why a DC motor needs a starter

    At standstill, back EMF is zero, so Ia = V / Ra becomes very large and can burn the armature. A starter adds resistance that is cut out as speed rises. Recall: what is zero at standstill?

  6. Fact 6 of 12

    Back EMF limits armature current

    Back EMF Eb = V - Ia x Ra. It grows with speed, so armature current falls as the motor speeds up. Recall: which quantity grows with speed and limits current?

  7. Fact 7 of 12

    3-point starter: for shunt motors

    It has three terminals: L (line), A (armature) and F (field). It carries a no-volt coil and an overload release. Used for shunt motors. Recall: which motor uses a 3-point starter?

  8. Fact 8 of 12

    4-point starter: for compound motors

    It has a fourth terminal for the series field, so the series and shunt fields are both connected. Used for compound motors. Recall: which motor uses a 4-point starter?

  9. Fact 9 of 12

    No-volt coil stops runaway on power cut

    It holds the starter handle ON while supply is available. If power fails, a spring returns the handle to OFF, protecting the motor. Recall: what returns the handle to OFF on power failure?

  10. Fact 10 of 12

    Overload release trips on heavy load

    It is in series with the armature. When current exceeds the safe limit it trips and cuts the supply. Recall: which starter part protects against overload current?

  11. Fact 11 of 12

    Start gently, like a Kerala bus

    A bus pulls away gently from a stop instead of jerking. A starter works the same way, letting current build up safely as the motor gathers speed. Recall: what does a starter limit at start?

  12. Fact 12 of 12

    Armature control wastes power as heat

    Losses in the series rheostat are I squared R, so efficiency drops at low speed. Electronic drives reduce this loss. Recall: which loss rises in the series rheostat?