QuizKerala

Do you know?

[BOTH] Transducers and sensors - part 2

12 facts. Swipe through the cards.
Free PSC questions in your emailLDC, LGS, prelims and more. Tell us your exam and get practice questions free.Sign up free
  1. Fact 1 of 12

    Seebeck effect: who discovered it?

    Thomas Johann Seebeck found in 1821 that two different metals joined at two temperatures make a voltage. This is the thermocouple principle. Recall: who discovered it? Answer: Seebeck.

  2. Fact 2 of 12

    Seebeck voltage formula

    Voltage equals S x (T hot - T cold). S is the Seebeck coefficient, in microvolts per °C. Recall: what does S stand for? Answer: Seebeck coefficient.

  3. Fact 3 of 12

    Type K: the most common thermocouple

    Type K (chromel-alumel) gives about 41 µV per °C and covers roughly -200 to 1260 °C. Why it helps: cheap and wide range. Kerala example: LPG stove flame-failure safety. Recall: which type is most common? Answer: Type K.

  4. Fact 4 of 12

    Why thermocouples need cold junction compensation

    A thermocouple measures a temperature difference, so the reference junction must be known. Cold junction compensation fixes this. Recall: what is the fix called? Answer: cold junction compensation.

  5. Fact 5 of 12

    Thermocouple needs no external power

    It generates its own voltage, so it needs no excitation current. Why it helps: rugged and fast for hot exhaust, like a bus engine. Recall: does a thermocouple need external power? Answer: No.

  6. Fact 6 of 12

    Pt100: 100 ohm at 0 °C

    A Pt100 RTD has 100 ohm resistance at 0 °C, and the number is in its name. Why it helps: platinum resistance rises steadily with heat. Recall: Pt100 resistance at 0 °C? Answer: 100 ohm.

  7. Fact 7 of 12

    Pt100 changes about 0.385 ohm per °C

    Its alpha is 0.00385 per °C, so resistance rises about 0.385 ohm per degree. Why it helps: the change is easy to measure. Recall: Pt100 resistance change per °C? Answer: about 0.385 ohm.

  8. Fact 8 of 12

    Three-wire RTD cancels lead resistance

    Long leads add resistance that looks like a temperature change. Three-wire or four-wire wiring cancels this error. Recall: what error do extra leads cause? Answer: lead resistance error.

  9. Fact 9 of 12

    RTD: the most linear and stable sensor

    Platinum RTDs are very linear and stable, usable from about -200 to 850 °C. Why it helps: standard for precise industrial and lab readings. Recall: which metal is used? Answer: platinum.

  10. Fact 10 of 12

    NTC thermistor: resistance falls with heat

    NTC means negative temperature coefficient. Resistance drops as temperature rises. Why it helps: the name shows thermal plus resistor. Recall: does NTC resistance rise or fall with heat? Answer: falls.

  11. Fact 11 of 12

    Thermistor: sensitive but nonlinear

    A thermistor changes resistance a lot for small temperature changes, but its curve is nonlinear. Why it helps: good for narrow ranges like water temperature. Recall: is thermistor response linear? Answer: No.

  12. Fact 12 of 12

    PTC thermistor: resistance jumps at a set temperature

    PTC resistance rises sharply above a set temperature. Why it helps: resettable overcurrent protection. Kerala example: pump motor protection. Recall: what does PTC stand for? Answer: positive temperature coefficient.