  1. Fact 1 of 12

    Shunt field: parallel with armature

    In a shunt generator the field is in parallel with the armature, so it gets full voltage and needs thin wire with many turns to keep its current small. Recall: which connection does a shunt field use? Answer: parallel.

  2. Fact 2 of 12

    Series field: in series with armature

    A series field carries the full load current, so it uses thick wire with few turns. Recall: which current does a series field carry? Answer: full load current.

  3. Fact 3 of 12

    Series generator: no load, almost no voltage

    With no load, a series generator's field current is nearly zero, so its output voltage falls to almost nothing. Recall: what is the series generator's voltage at no load? Answer: almost zero.

  4. Fact 4 of 12

    Shunt generator needs residual magnetism

    A shunt generator starts building voltage only if residual magnetism remains in its poles. Recall: what starts a shunt generator's voltage build-up? Answer: residual magnetism.

  5. Fact 5 of 12

    Shunt generator: armature current splits

    In a shunt generator, armature current equals load current plus shunt field current. Recall: armature current equals load current plus what? Answer: shunt field current.

  6. Fact 6 of 12

    Shunt generator voltage dips with load

    A shunt generator's terminal voltage falls a little as load rises, due to armature resistance and armature reaction. Recall: what two causes lower shunt generator voltage under load? Answer: armature resistance and armature reaction.

  7. Fact 7 of 12

    Compound generator has two field windings

    A compound generator carries both series and shunt field windings on the same poles. Recall: how many field windings does a compound generator have? Answer: two.

  8. Fact 8 of 12

    Cumulative compound: fluxes add

    In a cumulative compound generator the series and shunt fluxes add, so voltage stays nearly steady as load rises. Recall: in cumulative compound, do the fluxes add or oppose? Answer: add.

  9. Fact 9 of 12

    Differential compound: fluxes oppose

    In a differential compound generator the series flux opposes the shunt flux, so voltage drops sharply with load, which suits arc welding. Recall: in differential compound, do the fluxes add or oppose? Answer: oppose.

  10. Fact 10 of 12

    Series generator is poor for constant voltage

    A series generator's voltage rises with load, so it is unsuitable for supplying constant voltage to changing loads. Recall: is a series generator suited to constant voltage? Answer: no.

  11. Fact 11 of 12

    Short shunt versus long shunt

    In a short shunt compound generator the shunt field is across the armature only, while in a long shunt it is across armature plus series field. Recall: in which compound type is the shunt field across the armature only? Answer: short shunt.

  12. Fact 12 of 12

    Shunt field is high resistance

    Because the shunt field is across full voltage, its winding has high resistance and draws only a small current. Recall: is shunt field resistance high or low? Answer: high.