Do you know?
[SE] Line performance: efficiency and regulation - part 2
- Fact 1 of 12๐
Skin effect: AC hugs the wire's outer surface
AC current crowds to the outer surface of a wire, like a crowd at a bus door. Exam term: skin effect. Why: changing magnetic flux pushes current outward. Recall: what is this crowding called? Skin effect.
- Fact 2 of 12โก
Why ACSR cores carry little AC current
The steel core in an ACSR line adds strength, but AC current flows mostly in the outer aluminium layer. Exam term: skin effect. Kerala example: high-voltage towers on the grid. Recall: which metal carries most AC? Aluminium.
- Fact 3 of 12๐
Skin depth of copper at 50 Hz is about 9 mm
Skin depth is the depth where current density falls to 1/e of its surface value, about 9 mm in copper at 50 Hz. Formula: delta = sqrt(2 x rho / (omega x mu)). Recall: what gets smaller as frequency rises? Skin depth.
- Fact 4 of 12๐ฅ
Line loss grows with the square of current
Line loss is I^2R, so doubling the current makes the loss four times bigger. Exam term: I^2R loss. Kerala example: a thin extension cord gets hot when a pump draws heavy current. Recall: double the current, loss becomes how many times? Four.
- Fact 5 of 12๐
Higher voltage means lower line loss
For the same power, P = V x I, so higher voltage needs less current. Less current cuts I^2R loss sharply. Kerala example: the 11 kV feeder loses far less power than a 230 V line would for the same load. Recall: what must rise to cut loss? Voltage.
- Fact 6 of 12๐
Low power factor raises line current
The same kW at low power factor needs more current. Three-phase formula: I = P / (sqrt(3) x V x pf). Exam term: power factor. Kerala example: a pump motor with poor pf draws extra current from the line. Recall: low pf means more or less current? More.
- Fact 7 of 12๐งพ
Technical loss vs commercial loss
Technical loss is I^2R heating in wires and transformers. Commercial loss is power stolen or unbilled, like a bypassed meter. Exam term: AT&C loss. Kerala example: tampering with a KSEB meter is commercial loss. Recall: which loss is theft? Commercial loss.
- Fact 8 of 12๐งต
Thicker conductor, lower resistance
Formula: R = rho x L / A, so resistance falls as cross-section area A rises. Exam term: resistivity (rho). Why: a wider path lets current flow more easily. Kerala example: a thick cable for a three-phase pump lowers loss. Recall: does a thicker wire have more or less resistance? Less.
- Fact 9 of 12๐
Peaks at different times lower the total peak
Regions reach their peak demand at different times, so the combined peak is less than the sum of separate peaks. Exam term: load diversity. Why: spare capacity is pooled. Kerala example: evening demand is partly met from other states. Recall: what is this peak-timing effect called? Load diversity.
- Fact 10 of 12๐ค
Interconnection shares spare capacity
A linked grid lets surplus from one region support a shortage in another. Exam term: reserve sharing. Why: each region needs less spare generation on its own. Kerala example: KSEB draws power from the wider grid when local generation falls short. Recall: what is shared between regions? Spare capacity.
- Fact 11 of 12๐ก๏ธ
A bigger grid holds frequency steadier
A large interconnected grid absorbs a sudden generator trip better, so frequency dips less. Exam term: system inertia. Why: many running machines share the shock. Kerala example: a plant tripping in another state is felt less here. Recall: what term means resistance to frequency change? Inertia.
- Fact 12 of 12๐ฐ
Interconnection helps trade surplus power
Linked grids let surplus power be sold to a neighbour. Exam term: power exchange. Why: the cheapest plants run first across the whole grid, called merit order. Kerala example: Kerala buys power when its own dams run low. Recall: what order runs cheapest plants first? Merit order.